1.
Article | IMSEAR | ID: sea-189237

ABSTRACT

The purpose of this study was to evaluate surface characteristics of Reciproc (R25) WaveOne (WO) &WaveOne Gold (WOG) files using SEM before and after use. Methods: fifteen primary files from each system were scanned for surface defects before instrumentation at 10x-1000x. Each file was planned to be used to instrument six root canals and then examined under SEM after preparing three and six canals at same magnifications. Data were scored and statistically analysed using CHI –SQ and Anova tests (p≤ 0.05). Results: Surface defects were detected in all study groups with higher values in WO & WOG group before use. Surface defects significantly increased in both WO and WOG groups after use as compared to R25. WO & WOG group showed significantly greater defects including metal strips, pitting, craters, micro-cracks and blunt edges (p≤ 0.05). Conclusions: Wave One Gold file has a different metallurgy due to its gold finish that does not enhance its resistance to surface defects during clinical use. Wave One and Wave One Gold showed significant increase in surface defects after six canal use which limits their usage in more than one teeth in single patient.

2.
Article | IMSEAR | ID: sea-189235

ABSTRACT

Aim: Antibiotic loaded bone cement has been used extensively in orthopaedic surgery and in the treatment of osseous defects resulting from joint infection, osteomyelitis, osteitis. No endodontic investigation has used this type of material in the treatment of bony resorptive defects of the periapical lesions associated with failed endodontic therapy or periapical surgery. Therefore, this study was conducted with the use of gentamycin loaded bone cement, to assess healing ability of osseous defects in apical re-surgery cases after failed apical surgery. Methods: In all patients periapical lesions were surgically removed and gentamicin loaded bone cement was used as root end filling material and then carefully packed without pressure into the bony defect. Results: Long-term recall demonstrated clinical and radiographic healing and good tolerance of bone fill material by the periapical tissues. Conclusion: results from this study shows that gentamicin loaded bone cement is a biocompatible material and can be used effectively in apical resurgery cases for treating recalcitrant infectious osseous defects of periapical lesions associated with failed periapical surgery.

3.
Article | IMSEAR | ID: sea-188401

ABSTRACT

Background: Aim: To study the outcome of single visit surgical extrusion and immediate aesthetic restoration of 15 cases of crown root fracture. Methods: Involved a conventional surgical extrusion method with elevators and stabilization with semi rigid fiber splint followed by immediate aesthetic composite buildup for restoration of aesthetics. Root canal treatment was completed after 3 weeks of Calcium hydroxide intracanal medicament. Results: Follow up examinations varying between 6 and 18 months, revealed no evident radiographic and clinical signs of root resorption, periapical disease and more important, marginal bone loss/gingival recession in any case. Conclusion: Highly favorable results of this clinical study reveal that single visit surgical extrusion with immediate aesthetics of crown root fractures may be an alternative to time consuming orthodontic extrusion which may create severe esthetic and emotional problems to patient.

SELECTION OF CITATIONS
SEARCH DETAIL